AS32M- ANALYZER FOR QUICK AND DIRECT (WITHOUT CONVERSION) NO2 MONITORING

AS32M- ANALYZER FOR QUICK AND DIRECT (WITHOUT CONVERSION) NO2 MONITORING

Designed to alleviate potential disadvantages of the chemiluminiscence method and to provide the most accurate value for NO2 concentration measurements.

  • Direct and continuous monitoring of Nitrogen Dioxides
  • Provides fast and accurate NO2 measurements
  • Extremely compact, easy to use with minimal maintenance (periodic change of particle filter)
  • Completely autonomous, automatic and capable of detecting short events with high precision
  • Direct measurement of the sample - no chemical conversion required
  • Innovative technology plus touchscreen convenience (optionally)
  • US EPA Automated Equivalent Method
  • TÜV certified according EN 14211: 2012, EN 15267-1: 2009, EN 15267-2: 2009, VDI 4202-1: 2010 and VDI 4203-3: 2010

Applications:

  • Ambient air quality monitoring
  • Indoor air quality continuous monitoring
  • Mobile and fixe monitoring stations
  • Traffic stations: near-road, tunnels, canyon streets
  • Medical gases measurements...
  • NO2 measurement according to the European Directive 2008/50/CE

Features:

  • Direct and continuous monitoring of ambient NO2
  • Extremely compact, easy to use with minimal maintenance (periodic change of particle filter)
  • Completely autonomous, automatic and capable of detecting short events with high precision
  • Direct measurement of the sample - no chemical conversion required
  • Innovative technology plus touchscreen convenience (optionally)
  • Visible (450 nm) absorption measurement using patented Cavity Attenuated Phase Shift (CAPS) technology
  • Measurement of ambient concentrations to 1000 ppbv
  • Essentially interference-free
  • Insensitive to presence of varying levels of nitric oxide, aerosols, humidity and other trace atmospheric species
  • No Toxic Gas Emissions
  • Real-time synoptic flow diagram display
  • Linear Response (0-1000 ppbv)
  • Built-in USB port and serial interface (RS 232 / RS 422)
  • Full remote emulation of the analyzer
  • TCP/IP remote control with dynamic, multilingual interface, featuring intuitive navigation by pictograms
  • NEW: on board web server compatible with any internet browser. es@cloud™ user interface with online help for the display, configuration, maintenance, diagnostics or software updating of the analyser, remotely, from any PC, tablet or SmartPhone

Specifications:

  • Measurement Range: 0-1 ppm
  • Detection limit (2s): 0.1 ppb
  • Repetability standard deviation at zero: 0.05 ppb
  • Repetability standard deviation at a level of the hourly limit value (200μg/m3 ): 0.2 ppb
  • Short zero drift: 0.75 ppb (24h)
  • Short span drift: 1.5 ppb
  • Response time (rise): 16 s
  • Response time (fall): 16 s
  • Difference betwen rise time and fall time: <1s
  • Lack of fit (linearity)(residual from the linear regression function): <4%
  • Lack of fit (linearity) at zero (residual at zero): 0.6 ppb (24h)
  • Sensitivity coefficient of surrounding temperature (0 to 30°C)
  • Authonomy: up to one year of NO2 measurements (on 1/4 h sampling rate)
  • Valves block for selection of external zero and span gas
  • Sample dryer
  • Ethernet network connection
  • Integrated web-server with full remote emulation of the analyser

Certifications:

  • US EPA Automated Equivalent Method (FEM): EQNA-0913-210
  • TÜV certified to VDI 4202-1 : 2010, VDI 4203-3 : 2010, EN 14211 : 2012, EN 15267-1 : 2009 and EN 15267-2 : 2009

 more..