» Products» Газ анализатори» AS32M- ANALYZER FOR QUICK AND DIRECT (WITHOUT CONVERSION) NO2 MONITORING
AS32M- ANALYZER FOR QUICK AND DIRECT (WITHOUT CONVERSION) NO2 MONITORING
AS32M- ANALYZER FOR QUICK AND DIRECT (WITHOUT CONVERSION) NO2 MONITORING
Designed to alleviate potential disadvantages of the chemiluminiscence method and to provide the most accurate value for NO2 concentration measurements.
- Direct and continuous monitoring of Nitrogen Dioxides
- Provides fast and accurate NO2 measurements
- Extremely compact, easy to use with minimal maintenance (periodic change of particle filter)
- Completely autonomous, automatic and capable of detecting short events with high precision
- Direct measurement of the sample - no chemical conversion required
- Innovative technology plus touchscreen convenience (optionally)
- US EPA Automated Equivalent Method
- TÜV certified according EN 14211: 2012, EN 15267-1: 2009, EN 15267-2: 2009, VDI 4202-1: 2010 and VDI 4203-3: 2010
Applications:
- Ambient air quality monitoring
- Indoor air quality continuous monitoring
- Mobile and fixe monitoring stations
- Traffic stations: near-road, tunnels, canyon streets
- Medical gases measurements...
- NO2 measurement according to the European Directive 2008/50/CE
Features:
- Direct and continuous monitoring of ambient NO2
- Extremely compact, easy to use with minimal maintenance (periodic change of particle filter)
- Completely autonomous, automatic and capable of detecting short events with high precision
- Direct measurement of the sample - no chemical conversion required
- Innovative technology plus touchscreen convenience (optionally)
- Visible (450 nm) absorption measurement using patented Cavity Attenuated Phase Shift (CAPS) technology
- Measurement of ambient concentrations to 1000 ppbv
- Essentially interference-free
- Insensitive to presence of varying levels of nitric oxide, aerosols, humidity and other trace atmospheric species
- No Toxic Gas Emissions
- Real-time synoptic flow diagram display
- Linear Response (0-1000 ppbv)
- Built-in USB port and serial interface (RS 232 / RS 422)
- Full remote emulation of the analyzer
- TCP/IP remote control with dynamic, multilingual interface, featuring intuitive navigation by pictograms
- NEW: on board web server compatible with any internet browser. es@cloud™ user interface with online help for the display, configuration, maintenance, diagnostics or software updating of the analyser, remotely, from any PC, tablet or SmartPhone
Specifications:
- Measurement Range: 0-1 ppm
- Detection limit (2s): 0.1 ppb
- Repetability standard deviation at zero: 0.05 ppb
- Repetability standard deviation at a level of the hourly limit value (200μg/m3 ): 0.2 ppb
- Short zero drift: 0.75 ppb (24h)
- Short span drift: 1.5 ppb
- Response time (rise): 16 s
- Response time (fall): 16 s
- Difference betwen rise time and fall time: <1s
- Lack of fit (linearity)(residual from the linear regression function): <4%
- Lack of fit (linearity) at zero (residual at zero): 0.6 ppb (24h)
- Sensitivity coefficient of surrounding temperature (0 to 30°C)
- Authonomy: up to one year of NO2 measurements (on 1/4 h sampling rate)
- Valves block for selection of external zero and span gas
- Sample dryer
- Ethernet network connection
- Integrated web-server with full remote emulation of the analyser
Certifications:
- US EPA Automated Equivalent Method (FEM): EQNA-0913-210
- TÜV certified to VDI 4202-1 : 2010, VDI 4203-3 : 2010, EN 14211 : 2012, EN 15267-1 : 2009 and EN 15267-2 : 2009