MP101M- REAL TIME PARTICULATE MONITOR

MP101M- REAL TIME PARTICULATE MONITOR

The standard Beta gauge measurement Method ISO 10473 of the MP101M dust monitor allows, when used with the patented optical technology of the CPM module, the continuous and simultaneous measurement of fine particulates. A unique combination, providing exclusive benefits:

  • Precise beta attenuation monitoring of PM10, PM2.5, PM1 or TSP mass concentration (μg/m3)
  • Real time optical measurement of PM10, PM2.5, PM1 and TSP mass concentration (μg/m3) using a single inlet
  • Particulate counting (nb / L) per seven size ranges from 1 to 100 μm

Applications:

  • Ambient air quality monitoring
  • Indoor dust monitoring
  • Working places
  • Industrial areas

Features: 

  • True particulate concentration measurement, not influenced by the physico-chemical nature, color or shape of particulates
  • Fiberglass tape with 3 years of autonomy of continuous sampling with daily cycles (1200 cycles)
  • Programmable short sampling periods, from 1 to 24 h (2 h minimum recommended for PM 2.5)
  • C14 sealed flat source with ultra-low activity (unique)
  • Built-in reference gauge for calibration: no need for factory recalibration
  • RST temperature-regulated sampling tube to avoid evaporative losses of semi-volatile particulate matter
  • True volumetric air flow control with 3 atmospheric temperature and pressure sensors to avoid artefacts
  • Direct measurement of particulate concentration by granulometric size family PM10, PM2.5, PM1
  • Rugged instrument, not sensitive to vibration or humidity
  • Sliding drawer on the rear panel for easy access and maintenance
  • CPM optical module for real time optical counting of PM10, PM2.5 & PM1 (nb/cm3); measurement of the concentration (μg/m3)
  • Exclusive patented optical technology, guaranteing strictly no interference due to particulate nature
  • Automatic calibration of the real time continuous particulate module (CPM) to the reference measurement (ß gauge)
  • Optional integration of CPM between the inlet of the MP101M monitor and the RST: can be easily connected to all existing MP101M

Specifications:

MP101M beta attenuation monitor:

  • Measurement ranges: user-programmable, up to 10 000 μg/m3
  • Lower detectable limit: 0.5 μg/m3 (24h average)
  • Measurement cycles: 1/2, 1, 2, 3, 6, 12, 24 h, user selectable (up to 96 hours)
  • Sample collection period: 1/4, 1/2, 1, 2, 3 h, ..., user selectable
  • Counting time: 10 to 300 sec, user selectable
  • Beta Source: sealed Carbon 14 (1.6MBq±15%)
  • Detector: high performance Geiger-Müller counter
  • Sampling flow rate: 1 m3/h
  • Standard filter: fiberglass tape (width 35 mm, length 30 m); autonomy for 1,200 samples (>3 years of daily measurements)
  • Power supply: 230V/50Hz (115V/60 Hz)
  • Housing: 19’’ rack / 6U
  • Dimensions: 483 x 324 x 266 mm (W x D x H)
  • Weight: 15 kg ( without pump)
  • Operating temperature: +10 to +40 °C
  • Serial link: 1 RS 232/RS422
  • Ethernet (RJ45) and USB ports
  • On-board webserver with remote es@cloud interface included

CPM continuous particulate optical monitoring module:

  • Technology: light scattering
  • Max. number of counted particles: 200,000 / cm3
  • Optical source: red visible laser diode
  • Detector: photodiode
  • Accuracy: ± 5% (compared to the reference method over 24h)
  • Temporal resolution: 1 second
  • Dimensions: 285 x 131 x 67 mm (W x D x H)

Certifications:

Standard compliance: ISO 10473 : 2000

  • For PM10:

- US-EPA (EQPM-0404-151)

- EN 12341 (I-CNR 087/2004, F-LCSQA)

  • For PM2.5:

- EN 14907 (F-LCSQA)

- US-EPA (EQPM-1013-211)

- J-MOE PM 2.5 Type approved

  • Russia : GOSSTANDART, 1787
  • Italy : Certification CNR of equivalence to EN 12341 n°87/2004
  • Spain : Ministry of Industry and Energy 194-94
  • Poland : PIBJOR D- 8997 