DTP701 Stack flow meter

DTP701  Stack flow meter. Velocity and flow measurement by Pitot tube

Applications:

  • Municipal waste incinerators
  • Hazardous waste incinerators
  • Combustion plants
  • Petrochemical industries
  • Cement plants
  • Glass plants
  • Paper mills

Features:

  • a Pitot tube
  • a control unit including sensors for measurement of: 

- velocity

  • - temperature
  • static pressure
  • an internal microprocessor for calculation of the gas flow
  • 4 analog outputs (optional serial output)

Specifications:

  • Velocity ranges: 4 to 30 m/s
  • Gas temperature: maximum 550 °C
  • Control unit: IP 66 tight box, fibreglass reinforced polyester
  • Fixation: wall mount
  • Dimensions: 400 x 400 x 200 mm (HxWxD)
  • Weight: 8 kg approx.
  • Pitot/Temperature probe: 

- Diameter 33 mm

- Standardly equipped withDN 100/PN 20 or NFX 44-052 (others upon request)

  • Power supply: 80/240 V, 50/60Hz 100 VA
  • Compressed air: dry, oil free, 4 bars (for backflush) 